Velp HU 6 Hydrolysis

HU 6 Hydrolysis Unit

Optimum solution for the acid/basic hydrolysis of food and feed samples prior to solvent extraction for total fat analysis.

VELP Scientifica

1/3

Improves Analysis

  • Hydrolysis / digestion by acid or base
  • Ensures conformity with AOAC standard
  • No sample transfer – no sample loss
  • Crucibles go directly into SER 148 or SER 158

Operator Safety

  • Reduces handling to a minimum
  • Automatic extraction of unwanted fraction
  • No exposure to vapors

Recommendations

  • Select a glassware kit and accessories to match workload
  • Hydrolysis is carried out with hydrochloric acid for approximately 60 minutes at 170 °C.
    The hydrolyzed sample is then filtered in a glass crucible and washed with warm deionized water in order to eliminate the residues of hydrochloric acid

Product Code

Description Power Supply Code
HU 6 230 V / 50-60 Hz F30300110
HU 6 115 V / 50-60 Hz F30310110

Including

10002412 A00000097 A00000089
check
10002412EDPM tube Ø6,4X 11,2mm
check
A00000097Celite, 1 Kg
check
A00000089Glass sand, 2 Kg

Accessories

A00000086 A00000087 A00000088 A00000144 A00000089
    
A00000086Glass crucible P1 6pcs/box
    
A00000087Glass crucible P3 6pcs/box
    
A00000088Glass bottle for waste collection
    
A00000144Test tubes Ø 42×300 mm, 250ml 3pcs/box
    
A00000089Glass sand, 2 Kg
A00000097
A00000085required
A00000309required
A00000293required
A00000251
    
A00000097Celite, 1 Kg
    
A00000085Glassware kit 3 positions for HU 6
    
A00000309Crucible Holder for SER 148
    
A00000293Crucible holder HU 6 for SER158
    
A00000251IQ/OQ Manual
GENERAL FEATURES
Construction material: epoxy painted stainless steel structure
Number of samples: 6 samples
Set temperature: display visualization
Countdown: display visualization
Display: LCD
Number of programs: 20
Selectable language: I, F, UK, E, D, T
Power: 1350 W
Dimensions (WxHxD): 355x590x450 mm (14.0×23.2×17.7 in)
Weight: 14.5 Kg / 32.0 lb
PERFORMANCE
Temperature range: from room temp. to 200 °C
Temperature calibration: automatic
Stability of the heating block temperature: ± 0,5°C
Homogeneity of the heating block temperature: ± 0,5°C
Precision of the heating block temperature: ± 0,5°C
Reaching of set temperature: acoustic and visual signal

 

Preliminary Hydrolysis, Significant Benefits

Perform single or multiple samples at the same time. HU6 is required for a preliminary hydrolysis, both for acid and basic hydrolysis, of food and feed samples prior to solvent extraction with SER Series.

HU6 ensure fast heating and reduced time, with all the benefits of the aluminum block in terms of temperature transmission and homogeneity.

No sample transfer prevents any possible sample loss, as the same crucibles can be processed by the solvent extractor SER.

HU6 needs to be combined with a dedicated glassware to be ready to use.

Brochure & Leaflet

VELP Scientifica invites you to download brochures and leaflets in order to explore our premium quality solutions and to have all the major key arguments, features and specifications of a product in your hands, in any place, and at any time.

Discover our premium solutions and food analyzers ideal for research centers and companies for N/Protein Determination (Kjeldahl and Dumas), Solvent Extrac
Discover our premium solutions and food analyzers ideal for research centers and companies for N/Protein Determination (Kjeldahl and Dumas), Solvent Extrac
Learn more about our optimum solution for the acid/basic hydrolysis of food and feed samples prior to solvent extraction for total fat analysis.

Application notes

Choose among a comprehensive library of Application Notes / White Papers and learn more on how to optimize the performance of your VELP instruments. These documents offer typical analyses of well-known samples, together with official references and suggestions, to make you an expert!

It is always more important to know the ingredients and amount of all the components, as fat content, for different reasons, including legal and nutritiona

Comparison tables

Select the category of products you are interested in and this tool will give you an easy overview of what is available at VELP in order to find the product that is perfect for you. These comparison tables provide a brief description with side by side features from basic equipment to the most advanced analytical solutions.

The solvent extraction is used in a wide range of samples covering a variety of applications. Choose amo

Certifications

Our compliance to statutory rules and regulations worldwide.
With the CE mark, VELP Scientifica declares that the products are designed and manufactured in compliance with the essential safety requirements of the European Directive on Safety.
The Certification Body (CB) Certificate is an international program created by the IECEE for the acceptance of product safety test results among participating laboratories and certification organizations around the world.
The cNEMKOus mark ensures this product is designed and manufactured in compliance with the International Directive on Safety IEC/EN 61010-1. The cNEMKOus mark has the same legal status as any other NRTL/SCC accredited marks, for U.S. and Canada.

With the CE mark, VELP Scientifica declares that the products are designed and manufactured in compliance with the essential safety requirements of the Eur