Velp NDA 701 Dumas Nitrogen

NDA 701 Dumas Nitrogen Analyzer

A versatile and Cloud enabled Dumas Protein/Nitrogen Analyzer, able to perform precise nitrogen analysis and protein determination in a flash. It is the best solution for high productivity and offers unique benefits, being totally unsupervised.

VELP Scientifica

1/2

Exceptional Versatility

  • Preinstalled methods selectable in an instant
  • Controllable from PC with DUMAsoft™ software
  • Powerful, clear and detailed reporting software
  • Data storable in multiple formats for LIMS or PC

High Productivity

  • Flash determination of nitrogen & protein content
  • Automated analysis of preloaded samples (117 positions)
  • Totally unsupervised operation
  • Results produced 24/7/365

High Performance

  • Unmatched LOD, 0.003 mg N
  • RSD less than 0.5% with EDTA standard
  • Conforms to Good Laboratory Practice standard
  • Leak tests (zone or total) ensure optimum performance

Economical Operation

  • LoGas™ TCD with no reference gas required
  • Exceptionally low cost per analysis
  • Premium quality consumables
  • Low energy consumption
  • Lowest operator costs

Environmentally Friendly

  • Minimum possible waste & residues
  • Optimized life of consumables
  • Incorporates TEMS™ technology*

Cloud-Enabled Instrument

  • Effortlessly connect your instrument to the cloud in complete safety
  • Real time monitoring and notification via VELP Ermes Cloud Platform
  • Immediate Software Updates (OTA)
  • Access to your data via PC, smartphone and tablet
  • Create and share reports, track trend and get useful insights
    *Saving Time, Energy, Money & Space

Video

NDA 701, Analysis in a flash
Watch NDA 701 VELP Dumas Nitrogen Analyzer in action. NDA 701 is the exclusive VELP Scientifica solution for rapid, accurate and reliable Nitrogen/Protein determination using the Dumas technique and offering accurate and precise results. NDA 701 is ideal for high troughput, being fully automated and requiring just 3-4 minutes per analysis.

Product Code

Description Power Supply Code
NDA 701 230 V / 50-60 Hz F30800070

Including

A00000193 40001065 40001504 10003926 40001693
check
A00000193Start-up kit (1000 analyses)
check
40001065Autosampler with disc 1
check
40001504DUMASoft™ Software
check
10003926RS232 cable for balance
check
40001693USB cable for PC, 5m

Accessories

A00000194 A00000270 A00000271 TA00000378 A00000199
    
A000001941000 analyses kit
    
A000002702000 analyses kit
    
A000002714000 analyses kit
    
TA00000378Kit for TOC/sample preparation
    
A00000199Disc 2 for autosampler
A00000200 A00000201 A00000161 A00000198 A00000322
    
A00000200Disc 3 for autosampler
    
A00000201Disc 4 for autosampler
    
A00000161Quartz ash insert
    
A00000198Ceramic ash insert
    
A00000322Metallic ash insert
A00000353 A00000153 A00000260 A00000371 A00000262
    
A00000353Cleaning kit for metallic ash collector
    
A00000153Tin Foil Cups 36x36mm, 150pcs
    
A00000260Tin foils 50x50mm, 450 pcs
    
A00000371Silver foil 35×35 mm, 100 pcs
    
A00000262Mold for tin foils 50x50mm
A00000149 A00000317 A00000154 A00000240 A00000157
    
A00000149EDTA, 100 g
    
A00000317Super-Absorbent Powder, 10g
    
A00000154Quartz wool, 50 g
    
A00000240Vcopper™ High Reduction Efficiency, 470 g
    
A00000157Copper oxide, 50g
A00000320 A00000235 A00000236 A00000225 A00000162
    
A00000320Velpcatalyst with inert layer, 36g
    
A00000235Rice flour, 30g
    
A00000236High temperature sealing grease
    
A00000225Anhydrone, 454g
    
A00000162Quartz reactor tube
A00000321 A00000226 A00000158 A00000217 E00010012
    
A00000321Metallic reactor tube
    
A00000226Pre-Packed Reduction Reactor
    
A00000158Pre-Packed Combustion Reactor
    
A00000217Tin foil cup closing device
    
E00010012VELP Ermes 1 Year Connection
E00010036 A00000192
    
E00010036VELP Ermes 3 Years Connection
    
A00000192NDA IQ/OQ/PQ Manual

 

GENERAL FEATURES
Method of analysis: Nitrogen determination according to Dumas method (combustion)
Duration of analysis: 3/4 minutes
Detector: Innovative TCD autocalibrating
Sample weight: max 1g
Autosampler capacity: up to 4 discs, 30 positions each
Reproducibility (RSD): < 0.5% for EDTA standards (9.57%N)
Recovery: > 99.5%
Detection limit: 0.003 mg nitrogen
Helium (He): purity 99.999% (grade 5.0)
Oxygen (O2): purity 99.999% (grade 5.0)
Compressed air or Nitrogen (N2): purity 99.6 % (oil and water free)
Helium (He) pressure: 2 bar
Oxygen (O2) pressure: 2 bar
Connectivity Cloud via LAN or Wi-Fi
Interfaces: USB; RS232
Power: 1400 W
Power supply: 230 V / 50 – 60 Hz
Weight: 54 kg / 119 lb
Dimensions (WxHxD): 655x510x410 mm (H 690 mm with autosampler)
25.8×20.1×16.1 in (H 27.0 in with autosampler)

Video

NDA 701, Analysis in a flash
Watch NDA 701 VELP Dumas Nitrogen Analyzer in action. NDA 701 is the exclusive VELP Scientifica solution for rapid, accurate and reliable Nitrogen/Protein determination using the Dumas technique and offering accurate and precise results. NDA 701 is ideal for high troughput, being fully automated and requiring just 3-4 minutes per analysis.

Dumas Nitrogen Analyzer – Full Automation & Convenience

VELP Scientifica has designed convenience into the NDA 701 Dumas Nitrogen Analyzer to let the user concentrate on evaluating the results that are produced in just 3 to 4 minutes per sample.
Once up to 4 discs (30 positions each) have been loaded, press the start button and walk away.

With the best limit of detection on the market and an RSD lower than 0.5% for EDTA, the user is assured of high precision results.

NDA 701, the ideal solution for high throughput, being fully automated and able to run 24/7.

Dumas Nitrogen Analyzer – NDA 701 Working Process

The Dumas method starts with a combustion to burn the sample, obtaining elemental compounds. Water is removed by a first physical trap (DriStep™), positioned after the combustion, and a second chemical one. Between the two, the elemental substances passed through a reduction furnace. The auto-regenerative CO2 adsorbers let pass only the elemental nitrogen that is detected by the LoGas™ innovative Thermal Conductivity Detector (TCD) with no requirement for a reference gas.

Dumas Nitrogen Analyzer – DUMASoft™, Simple Data Management

All the information will be constantly monitored from the main screen, including the real time graph. A wide library of methods is pre-installed to support the user with valuable information on the analysis.
It’s also possible to create a library of the calibration curves, in order to be always ready to use the most suitable one.

At any time, a leak test can be performed, to check that the system is completely sealed and no gases comes out.
After the analysis, the user can create customized test report, with lots of information about the lab and its own logo.

Dumas Nitrogen Analyzer – Reliable Autosampler

The NDA 701 autosampler provides high-quality performance, both for the sample loading and the sample conditioning, where the sample is stored into a dedicated room and purged with Helium in order to eliminate any trace of nitrogen present in the atmosphere before starting the analysis.
It can stand up to 4 discs simultaneously for an enhanced productivity.
The same autosampler is suitable for samples of any matrix (liquid, solid and semi-solid) up to 1 gram.

Dumas Nitrogen Analyzer – Specific Accessories for High Flexibility

NDA 701 is equipped with numerous accessories designed to simplify the operation.
A specific device simplifies the sample preparation for liquids; spatulas and syringes esnure correct transfer of the sample into the capsules.
In addition, VELP Scientifica produces also the main consumables, ensuring premium performance, as both the analyzer and the consumables come from the same source.

Dumas Nitrogen Analyzer – Accuracy and Precision

Discover the reliability of the NDA 701, as shown by the very low detection limit (0.003 mg N) and the good RSD% (<0.5% with EDTA standard). The unit can process up to 1 gram of samples, but also with small quantities (around 200 mg) NDA 701 gives optimum results with minimum consumption. No need for higher quantities as the results will be the same.

Monitor Your Instrument Anytime, Anywhere with VELP Ermes

The cloud technology will reduce your daily manual tasks and repetitive operations thanks to real-time monitor and control of your NDA. Immediate event and alarm notification will inform you about your analyses and the remote analysis interruption guarantees peace-of-mind and the total control of your process.

Safely access to your instrument data and working condition trough VELP Ermes web platform. Secure your recent data on cloud and share your reports with your peers, anytime, anywhere.

Be sure to have always the best performance and new features with OTA software updates.

Dumas vs. Kjeldahl

DUMAS

For High Productivity, non-stop performance
Time Saving, few minutes required
Moderate Running Costs
Totally Unsupervised, fully automated
Dry Chemistry
No chemicals
Eco-friendly, less residues and wastes
Increasingly Used Method, new technique
RSD%, < 0.5% (with yeast – 2.33% N)
Sample Homogenization, 0.5 mm particle size

KJELDAHL

For Low Productivity, non-continuous operation
Time-consuming, analyses last hours
Affordable Equipment Cost
Partly Unsupervised, not entirely automated process
Wet Chemistry, uses chemicals
Costly Wastes Produced, residues must be disposed of
Worldwide Official Method, still the traditional technique
RSD%, < 1% (with yeast – 2.28% N)
Sample Homogenization, 1 mm particle size

Brochure & Leaflet

VELP Scientifica invites you to download brochures and leaflets in order to explore our premium quality solutions and to have all the major key arguments, features and specifications of a product in your hands, in any place, and at any time.

Improve your laboratory experience with secure VELP Ermes Cloud Platform and access to your VELP instruments working conditions and data anytime and anywhe
Discover our premium solutions and food analyzers ideal for research centers and companies for N/Protein Determination (Kjeldahl and Dumas), Solvent Extrac
Learn more about our range of Dumas Nitrogen/Protein Analyzer, able to perform precise nitrogen analysis and protein determination in a flash and with an u
Learn more about our Dual Carrier Gas Dumas Protein/Nitrogen Analyzer, able to perform precise nitrogen analysis and protein determination in a flash with
Learn more about our wide range of superior quality consumables for the day-to-day operation of your NDA 701 & NDA 702.
Learn more about the Dumas principle, first described by Jean-Baptiste Dumas over a century and a half ago (1831).
Discover our premium solutions and food analyzers ideal for research centers and companies for N/Protein Determination (Kjeldahl and Dumas), Solvent Extrac
Learn more about our range of Dumas Nitrogen/Protein Analyzer, able to perform precise nitrogen analysis and protein determination in a flash and with an u

Application notes

Choose among a comprehensive library of Application Notes / White Papers and learn more on how to optimize the performance of your VELP instruments. These documents offer typical analyses of well-known samples, together with official references and suggestions, to make you an expert!

 suggestions, to make you an expert!
Monitoring of the protein content during the brewing process is important to ensure the survival, growth, and productivity of the yeast used to convert sugars to ethanol and carbon dioxide.

 

Certifications

Our compliance to statutory rules and regulations worldwide.
With the CE mark, VELP Scientifica declares that the products are designed and manufactured in compliance with the essential safety requirements of the European Directive on Safety.
The Certification Body (CB) Certificate is an international program created by the IECEE for the acceptance of product safety test results among participating laboratories and certification organizations around the world.
The cNEMKOus mark ensures this product is designed and manufactured in compliance with the International Directive on Safety IEC/EN 61010-1. The cNEMKOus mark has the same legal status as any other NRTL/SCC accredited marks, for U.S. and Canada.

With the CE mark, VELP Scientifica declares that the products are designed and manufactured in compliance with the essential safety requirements of the Eur